KTI - SAUTER CombiMaster (CM)

The KTI – SAUTER CombiMaster is used when the fresh concrete has to be heated in winter before processing and cooled in summer.

The CombiMaster contains a fully-fledged heating system and refrigeration system in one unit. This ensures the provision of feed water, which is cooled in summer and heated in winter. Likewise, cold air is generated in parallel in summer and hot air in winter for silo cooling or heating.

The CombiMaster is the only solution on the market that offers such versatile and flexible use.
 

Plant information

KTI – SAUTER CombiMaster contains a complete refrigeration system for active cooling of water and air. Likewise this contains two heating units for heating water and air. Heating and cooling, however, share the periphery. This has the unbeatable advantage that only one water pipe and one air pipe must be laid from the CombiMaster to the concrete batching plant. In addition, the CombiMaster is very compact, as the plants share one machine room. Winter operation In the winter, a KTI – SAUTER hot water system (HWS) heats the fresh water up to +85°C. A KTI – SAUTER hot air system (OLH) is responsible for heating the cold ambient air in order to heat the silos with the hot air. Both systems can be operated independently of each other, which is particularly useful in the transitional period. enormous savings brings with it. Summer operation In summer, a glycol chiller installed on the roof provides the required cooling capacity. The cold glycol is pumped through both a plate heat exchanger and an air register. In the plate heat exchanger Fresh water cooledwhich is then buffered in the boiler of the hot water system. In the air register, the ambient air is cooled before it flows into the silos. So unlike other products, the CombiMaster actually provides Cold air and not only ambient air is available for rock cooling.

The most important details at a glance

130

°C Hot air

85

°C Hot water

7

°C Cold air

4

°C Cold water

Your advantages of a KTI - SAUTER CombiMaster

  • The KTI - SAUTER CombiMaster is a All-In-One System for heating and cooling.
  • The KTI - SAUTER CombiMaster enables a trouble-free concrete production all year round.
  • The KTI - SAUTER CombiMaster is highly mobile and very space saving due to the container construction.
  • The KTI - SAUTER CombiMaster Reduces capital expenditures.

Product details

Winter operation
Heating capacity
600 kW
Hot water quantity
5 m³/h
Hot water temperature
85 °C max.
Fresh water inlet temperature
5 °C
Heating power via air
300 kW
Hot air temperature
130 °C
Ambient temperature min.
-10 C°
Summer operation
Cooling capacity
257 kW
Cold water quantity
5 m³/h
Cold water temperature
4 °C min.
Fresh water inlet temperature
15 °C
Cooling capacity via air
177 kW
Cold air temperature
7 °C
Ambient temperature max.
35 °C

Gallery​

Complementary products

CombiWater

With the KTI – SAUTER CombiWater, you can produce ice water and hot water – with just one system.

Hot water concrete heater

The KTI – SAUTER hot water systems (HWS) are used in the production of concrete, especially winter concrete.

Hot air silo heaters

The KTI – SAUTER hot air units (OLH) are used in a concrete plant to heat silos in winter.

Cold Air Plants for Aggregate Cooling

KTI cold air plants are specially designed to cool large quantities such as gravel and other aggregates efficiently, quickly and economically during concrete production.

Containerized Water Chiller Plant

KTI containerized water chiller plants are used in the cooling of concrete to provide addition water at 3 – 5 °C.

Insulated water tanks

KTI offers you a complete range of perfectly insulated water tanks.

Project consulting​

Our experts will be happy to support you in the planning and implementation of your project.